User Manual for FD100PRO Multi-functional Detector

User Manual for FD100PRO Multi-functional Detector – Safe Vault Emergency Power Supply – Battery Voltage Detection – Remote Current Leakage Detection – Infrared Remote Control Detection – Oscilloscope


I. Product Overview
FD100PRO is a multi-functional detection device that integrates remote frequency data detection, current and voltage monitoring, infrared remote control analysis, adjustable power output, and simple oscilloscope functions. It is suitable for electronic maintenance, equipment debugging, and infrared remote control detection, etc.
II. Equipment Components Description
Power Switch: Controls the start and stop of the device.
Quick Keys (3): Quickly enter functions.
Dial Switch:
Left and right movement: Switch function modes.
Press downward: Confirm operation or switch sub-menu (such as voltage output adjustment confirmation, oscilloscope sampling frequency adjustment).
Interface A: DC 5V power input port (supports power bank supply).
Interface B: Function expansion port (requires insertion of matching cable).
Summer City
III. Function Operation Guide
1. Startup and Basic Operations
Power On: Turn the power switch to the “ON” position.
Mode Switching: Switch functions by moving the dial switch left and right, or directly enter the corresponding mode using the quick keys.
2. Frequency and Data Detection
Operation Steps: The device displays the real-time frequency value (range: 0 – 999 MHz).
Press “Data Detection” to detect remote data. Use “Data Comparison” to verify data consistency (√ indicates consistency, × indicates abnormality).
3. Current/Voltage Detection and Leakage Detection
Current Detection:
Adjust the dial switch to set the output voltage (e.g., 12V).
Connect the measured device with wire clips (red clip positive, black clip negative).
The current of the device should be < 10uA when it is powered on, and it can be measured using the remote control.
Calibration: If the battery value is abnormal, press the dial switch for reset.
Voltage Detection:
Directly measure the battery voltage, DC 0 – 28V.
4. Infrared Data Detection
The red light of the device indicates that an infrared signal has been detected, and the code can be analyzed.
5. Adjustable Power Output
Operation Steps:
Adjust the dial switch to set the output voltage (1.5V – 16V, maximum current 100mA).
Connect the load device through Interface B, and the blue light will be on when the output is stable (such as fingerprint lock, safe vault).
6. Simple Oscilloscope Function
Operation Steps:
Press the dial switch to select the sampling frequency.
Left/right movement of the dial switch can pause or resume waveform display.
IV. Precautions
Calibration of current detection: If the value is abnormal after connecting the wire clips, you can long press the dial switch for calibration.
Load Limitation: The adjustable power output has a maximum current of 100mA and must not be overloaded.
Interface Protection: Ensure the positive and negative poles are correct when inserting the cable to avoid short circuit (indication light abnormal prompt).
Environmental Requirements: Avoid humid and high-temperature environments, and keep away from strong magnetic fields.
V. Technical Parameters
Frequency Detection Range: 0 – 999 MHz
Current Detection Range: 0 μA – 150 mA
Voltage Detection Range: DC 0 – 28 V
Adjustable Power Output: DC 1.5V – 16V, maximum current 100mA
Oscilloscope Sampling Frequency: Adjustable (as displayed on the screen)
Power Input: DC 5V 1A (Interface A)
VI. Maintenance and Care
Avoid severe vibration or dropping.
VII. After-sales Service
If there is a malfunction, contact the customer service, and we will provide professional support.
FD100PRO – Make detection more efficient, make maintenance simpler!

Scroll to Top